BA505 – Latest A Series The most feature-rich SNMP card
BA505 – Latest A Series The most feature-rich SNMP card
The BA505, as a mainstream card in the latest A series of SNMP cards, not only integrates and inherits all the functions of the previous T/X/Y series but also adds many practical new features and enhances security.
The BA505 has improved the security of access methods, increased the diversity of event notifications, refined the statistics of UPS data, and expanded the ways for third parties to obtain UPS data.
The BA505, as a mainstream card in the latest A series of SNMP cards, not only integrates and inherits all the functions of the previous T/X/Y series but also adds many practical new features and enhances security.
The BA505 has improved the security of access methods, increased the diversity of event notifications, refined the statistics of UPS data, and expanded the ways for third parties to obtain UPS data.


Data statistics
Enumerate the event records in days in calendar form and make statistics in pie charts. The UPS data changes in days are displayed in a linear graph, and the data statistics are carried out, showing the maximum value, minimum value, average value, variance and standard difference.

Network Connection
Support traditional wired network access; Support inserting compatible USB wireless network card for wireless network access; You can also enable the BA505 hotspot function to access the BA505 web management interface in an environment without a network.

Event notification
Support the original UPS event notification by email and SMS; Added UPS event notification via wechat, Skype, Telegram and LINE.

Access Method
Support HTTPS access, HTTPS protocol supports the latest TLS v1.3, public key length supports 2048 bits; Support HTTP/HTTPS, TELNET/SSH, FTP/FTPS three modes of independent account and password Settings, and can record the login or exit time and IP address; For HTTP/HTTPS or TELNET/SSH login, you can enable the RADIUS or LDAP service for login authentication. Users can also set the automatic upgrade of BA505 through FTP.

Get data
Support through SNMP access third-party monitoring platform, and support for the latest security level v3 version, MD5 authentication protocol/SHA/SHA244 / SHA256 / SHA384 / SHA512, private protocol support DES/AES - 128 / AES - 192 / AES - 256. UPS data monitored by BA505 can be obtained through Modbus, and can be connected through TCP or RS485 interface. Support BACnet to obtain UPS data monitored by BA505; And users can turn on or off Modbus and BACnet services according to their own network security requirements; Log in and out time and IP address of SNMP, Modbus or BACnet.

File management
Add file management function to the web management interface, you can visually view the log files in BA505 and the files that have been connected to the U disk; This function can be used to upload, download or delete BA505 log files or U disk backup log files or firmware files; Using the firmware files in the USB flash drive, you can use the Netility Web function in the web management interface to upgrade the firmware of other SNMP cards (including other series) in the same LAN. Added the Syslog function to automatically back up event logs and UPS data logs to the Syslog server.

Network Connection
Support traditional wired network access; Support inserting compatible USB wireless network card for wireless network access; You can also enable the BA505 hotspot function to access the BA505 web management interface in an environment without a network.

Access Method
Support HTTPS access, HTTPS protocol supports the latest TLS v1.3, public key length supports 2048 bits; Support HTTP/HTTPS, TELNET/SSH, FTP/FTPS three modes of independent account and password Settings, and can record the login or exit time and IP address; For HTTP/HTTPS or TELNET/SSH login, you can enable the RADIUS or LDAP service for login authentication. Users can also set the automatic upgrade of BA505 through FTP.

Get data
Support through SNMP access third-party monitoring platform, and support for the latest security level v3 version, MD5 authentication protocol/SHA/SHA244 / SHA256 / SHA384 / SHA512, private protocol support DES/AES - 128 / AES - 192 / AES - 256. UPS data monitored by BA505 can be obtained through Modbus, and can be connected through TCP or RS485 interface. Support BACnet to obtain UPS data monitored by BA505; And users can turn on or off Modbus and BACnet services according to their own network security requirements; Log in and out time and IP address of SNMP, Modbus or BACnet.

Data statistics
Enumerate the event records in days in calendar form and make statistics in pie charts. The UPS data changes in days are displayed in a linear graph, and the data statistics are carried out, showing the maximum value, minimum value, average value, variance and standard difference.

Event notification
Support the original UPS event notification by email and SMS; Added UPS event notification via wechat, Skype, Telegram and LINE.

File management
Add file management function to the web management interface, you can visually view the log files in BA505 and the files that have been connected to the U disk; This function can be used to upload, download or delete BA505 log files or U disk backup log files or firmware files; Using the firmware files in the USB flash drive, you can use the Netility Web function in the web management interface to upgrade the firmware of other SNMP cards (including other series) in the same LAN. Added the Syslog function to automatically back up event logs and UPS data logs to the Syslog server.



SNMPView Lite is a new feature in the BA505 network interface that allows centralized monitoring and management of nine netagents, including viewing UPS status and records, and easy setup of SNMP v1/v2 and manual addition of SNMP v3.
SNMPView Lite is a major new feature added to the BA505 web management interface, allowing the BA505 to centrally monitor nine other NetAgents (including the local one) in the network.
SNMPView Lite can easily search for and add monitoring for nine NetAgents (including the local one) in the LAN with just one click, provided that SNMP v1 and v2 are enabled on the other NetAgents. If a NetAgent only has SNMP v3 enabled, it needs to be added manually. After successfully adding monitoring, you can view the current UPS status of all monitors in the “Nine-grid” view on the web interface.
SNMPView Lite also allows you to view event records and data records for the nine successfully added NetAgents.



SNMPView Server is a large-scale centralized monitoring and management platform for UPS based on the network. It needs to be installed and set up on a server or mainstream computer and connected to the network for use. The number of UPS units that can be monitored depends on the server configuration and network quality. However, compared to the free software SNMPView, SNMPView Server can monitor a much larger number of devices and provides more diverse information.
The home page displays the UPS status of all nodes and the status of the connected environment detection host.
You can set region information, including the region directory and the NetAgent that monitors the UPS in the region. You can set basic information, including the name of the network, associated with the upper-level network, the person in charge of the network, the person in charge of the contact information, the person in charge of the email address.
You can set basic information, including SNMP, IP address, and UPS type. You can set alarm information, including email, SMS, voice (local), and TRAP alarms. The UPS and battery start time and next replacement time can be set. You can set the UPS responsible person and other related information.
You can upload a map by yourself. Netagents to be monitored are distributed in dots on the map. Netagents in which UPS events are occurring are marked with red dots.
Event report statistics can be displayed in pie charts, bar charts, and tables. UPS data reports can be displayed in curves and tables.
The alarm level can be customized, and the alarm level can be assigned to NetAgent events and UPS events. The alarm mode can be set by email, voice, and SMS.
Users can set a super administrator and a common administrator. The super administrator assigns the common administrator permission to monitor NetAgent or areas.
System logs include user operation logs, email logs, and SMS logs. Can establish the responsible person’s address book; And automatic management of the platform’s database, including backup and cleanup.